ConstructCraft

Light steel frame and wood frame walls (sub-project 4)

Part of the Structure tab redesign; the user asked for “permitir LSF e SF” (“allow LSF and SF”). The heavy steel frame (SF) is covered by 2a (grid frames) and 2b (steel buildings). This sub-project frames walls: light steel framing (LSF) with cold-formed studs and tracks, and wood framing with sawn timber studs and plates.

It uses the shared member-host mechanism (cc_core::member_host) from sub-project 3. The user told me to make the design decisions alone.

Goals

Out of scope:

Layout

The wall frame is the body centerline (Project::wall_axis), with u along the wall from 0 to length L. The base is wall_base_z and the top is wall_top_z. Let t be the track or plate depth (the height of the track type’s section box) and n the number of top plates (1, or 2 with double_top).

Defaults

system studs (column type of) tracks/plates headers/sills
LightSteel Ue 90x40x12x0,95 (NBR6355-Ue) U 92x38x0,95 (NBR6355-U) Ue 140x40x12x0,95
Wood Peça 6x8 (Timber-Sawn) Peça 6x8 Peça 6x16

All of them are made through catalog_type.

Engine

wall_framing_create takes:

It creates one framing per wall in one undo step. It refuses curved walls and walls that already have framing, before any edit, and returns { framings: [{ id, wall, members }] }.

element_get and element_set handle the parameters as for the other hosts. wall cannot be changed.

Views

Plans draw nothing for the host itself. The studs show as columns in the plan cut. To select the host, the members’ properties show a Framing row whose button selects it. In elevations and sections the members are drawn as usual.

App

Testing

Decisions made while planning

These amend the sections above where they differ.